International Journal of Prosthodontics and Restorative Dentistry

Register      Login

VOLUME 11 , ISSUE 1 ( January-March, 2021 ) > List of Articles

CLINICAL TECHNIQUE

Digital Fabrication of a Repositioning Jig for Multiunit Abutments Placement: A Dental Technique

Majed Altoman, Hatem Alqarni, Mohammed Alfaifi, Mathew T Kattadiyil

Keywords : 3D Printing, Abutments, CAD/CAM, Complete denture, Dental Implants, Dental prostheses, Edentulism, Full mouth rehabilitation, Rapid prototyping, Stereolithography

Citation Information : Altoman M, Alqarni H, Alfaifi M, Kattadiyil MT. Digital Fabrication of a Repositioning Jig for Multiunit Abutments Placement: A Dental Technique. Int J Prosthodont Restor Dent 2021; 11 (1):54-57.

DOI: 10.5005/jp-journals-10019-1288

License: CC BY-NC 4.0

Published Online: 12-08-2021

Copyright Statement:  Copyright © 2021; The Author(s).


Abstract

Aim: Designing and fabrication of a digital computer-aided design and computer-aided manufacturing (CAD-CAM) implant abutment repositioning jig (IARJ) by using additive manufacturing. Background: The implant-supported fixed complete denture (ISFCD) is a predictable treatment option in the restoration of the edentulous arch situations. Advancements in CAD-CAM have improved the workflow efficiency in ISFCD fabrication. Technique: An implant abutment repositioning jig is used to ensure easy and accurate placement of angled multiunit abutments (MUAs). This report describes a technique, a digital workflow, and fabrication of IARJ. Conclusion: Use of digital technology in IARJ fabrication offers certain advantages such as an easy archiving STL file, fabrication for future maintenance or replacement of MUAs if needed.


HTML PDF Share
  1. Brånemark PI, Adell R, Breine U, et al. Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 1969;3:81–100.
  2. Worni A, Kolgeci L, Rentsch-Kollar A, et al. Zirconia-based screw-retained prostheses supported by implants: a retrospective study on technical complications and failures. Clin Implant Dent Relat Res 2015;17(6):1073–1081. DOI: 10.1111/cid.12214.
  3. Moscovitch M. Consecutive case series of monolithic and minimally veneered zirconia restorations on teeth and implants: up to 68 months. Int J Periodont Res Dent 2015;35:314–323.
  4. Maló P, de Araújo Nobre M, Borges J, et al. Retrievable metal ceramic implant-supported fixed prostheses with milled titanium frameworks and all ceramic crowns: retrospective clinical study with up to 10 years of follow-up. J Prosthodont 2012;21(4):256–264. DOI: 10.1111/j.1532-849X.2011.00824.x.
  5. Paniz G, Stellini E, Meneghello R, et al. The precision of fit of cast and milled full-arch implant-supported restorations. Int J Oral Maxillofac Implant 2013;28(3):687–693. DOI: 10.11607/jomi.2990.
  6. Jacobson Z, Peterson T, Kim WD. Positioning jig for implant abutments: procedures and clinical applications. J Prosthet Dent 1996;75(4):435–439. DOI: 10.1016/S0022-3913(96)90038-4.
  7. Knudson RC, Williams EO, Kemple KP. Implant transfer coping verification jig. J Prosthet Dent 1989;61(5):601–602. DOI: 10.1016/0022-3913(89)90284-9.
  8. Papazian S, Morgano SM. Four uses of a disposable implant mount. J Prosthet Dent 1998;79(2):222–225. DOI: 10.1016/S0022-3913(98)70220-3.
  9. Papazian S, Morgano SM. Use of aluminum strips to fabricate verification jig for an implant-supported fixed partial denture. J Prosthet Dent 1998;79(3):350–352. DOI: 10.1016/S0022-3913(98) 70250-1.
  10. Di Vitale N, Tung F, Goldstein G. A technique to verify or correct analogue position and soft tissue profile on an implant working cast. J Prosthet Dent 2009;102(3):137–140. DOI: 10.1016/S0022-3913(09)00098-5.
  11. Farah RI, Alshabi AM. Technique to verify the accuracy of a definitive cast before the fabrication of a fixed dental prosthesis. J Prosthet Dent 2016;116(3):325–327. DOI: 10.1016/j.prosdent.2016. 03.010.
  12. Al-Abbas H, Al-Ajmi M, Pipko DJ. A positioning jig to verify the accuracy of implant abutments. J Prosthet Dent 2002;87(1):115–116. DOI: 10.1067/mpr.2002.118920.
  13. Wu YL, Wu AY. A method of fabricating an accurate repositioning device for relocating multiple multiunit abutments. J Prosthet Dent 2017;118(4):564–566. DOI: 10.1016/j.prosdent.2017.01.009.
  14. Hess TA, Ramos Jr V, Buglione D. A technique to guide replacement of multiunit abutments supporting an existing implant-supported fixed complete denture. J Prosthet Dent 2020;124(3):270–273. DOI: 10.1016/j.prosdent.2019.07.016.
  15. Chen L, Lin WS, Polido WD, et al. Accuracy, reproducibility, and dimensional stability of additively manufactured surgical templates. J Prosthet Dent 2019;122(3):309–314. DOI: 10.1016/j.prosdent.2019.02.007.
  16. Ammoun R, Dalal N, Abdulmajeed AA, et al. Effects of two postprocessing methods onto surface dimension of in-office fabricated stereolithographic implant surgical guides. J Prosthet Dent 2020;30(1):71–75.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.