EDITORIAL |
https://doi.org/10.5005/jp-journals-10019-1411 |
Current Evidence on the use of PEEK as Implant Abutment Material
1Consultant Prosthodontist & Implantologist, Amar 1 Hospital, Aurai, Bhadohi, Uttar Pradesh, India
2Department of Prosthodontics, Sri Siddhartha Dental College and Hospital, Tumkur, Karnataka, India
Corresponding Author: Sunil K Mishra, Consultant Prosthodontist & Implantologist, Amar 1 Hospital, Aurai, Bhadohi, Uttar Pradesh, India, Phone:+91 7697738478, e-mail: sunilmsr200@yahoo.co.in
How to cite this article: Mishra SK, Chowdhary R. Current Evidence on the use of PEEK as Implant Abutment Material. Int J Prosthodont Restor Dent 2023;13(2):55-55.
Source of support: Nil
Conflict of interest: None
Rehabilitation of partially or completely edentulous arches with dental implants is a well-known treatment procedure in dentistry. Titanium implants have been used for a long time because of their good biocompatibility and high corrosion resistance. However, in cases where soft tissue thickness is less (<2 mm), titanium, due to its metallic nature, causes graying of the surrounding implant tissues. This results in compromised esthetics, which needs a metal-free abutment to overcome the same.1 Recently, polyetheretherketone (PEEK), a synthetic tooth-colored polymeric thermoplastic material, has been of great interest to researchers for its use as implant abutment material.2,3
Ortega-Martínez et al.,3 in an in vitro study, evaluated the functional and mechanical properties of PEEK as dental implant abutments so that it can be used as a nonmetallic alternative to titanium abutments. They found that the loss of torque with titanium abutments was approximately 10% when compared to PEEK, having a 50% loss. Under dynamic loading, all PEEK abutments showed microleakage, while only 8.4% of the titanium abutments showed microleakage. Matos et al.,4 in an in vitro study, evaluated the biomechanical behavior of different sizes of PEEK abutments on titanium implants. They concluded that PEEK abutments should be used with care, as they resist only moderate forces. There was a plastic strain and large vertical displacement seen with PEEK abutments at the abutment-implant junction. They suggested that the use of PEEK abutments should be restricted to temporary restorations in patients without parafunction and requiring rehabilitation in the anterior region.
Ragupathi et al.5 analyzed the wear resistance of PEEK and titanium implant abutments under cyclic loading. They found that titanium abutments have more wear resistance than PEEK abutments; however, the difference is statistically insignificant. PEEK can be considered for use as a definite abutment. Milinkovic et al.,6 in their immunohistochemical and histological study, had compared the soft tissues’ reaction to titanium and PEEK healing abutments. They found that PEEK healing abutments seem to cause severe tissue inflammatory response. These were mainly produced by the activation of plasmacytes and histocytes. In the case of titanium healing abutments, the inflammatory reaction was of lower intensity and mainly triggered by B-cells.
Ghazal-Maghras et al.,7 in their systematic review, evaluated the functional and mechanical properties of PEEK as abutments and its efficacy as a substitute for titanium abutments. The data available has shown insufficient evidence in favor of PEEK being used as definitive abutments, which can replace titanium. There are very limited in vivo studies available comparing PEEK and titanium abutments. Most of the research done on PEEK as abutment material were in vitro studies, which had not favored PEEK as a definite abutment.
More long-term in vivo studies are needed using PEEK as a definite abutment so that it can be made clear whether it is an available alternative to titanium or not. Currently, the use of PEEK must be restricted to temporary abutments in the anterior region in patients without any parafunction habits.
ORCID
Sunil K Mishra https://orcid.org/0000-0003-4844-1844
Ramesh Chowdhary https://orcid.org/0000-0002-3254-741X
REFERENCES
1. Bishti S, Strub JR, Att W. Effect of the implant-abutment interface on peri-implant tissues: a systematic review. Acta Odontol Scand 2014;72(1):13–25. DOI: 10.3109/00016357.2013.799712
2. Najeeb S, Zafar MS, Khurshid Z, et al. Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics. J Prosthodont Res 2016;60(1):12–19. DOI: 10.1016/j.jpor.2015.10.001
3. Ortega-Martínez J, Delgado LM, Ortiz-Hernández M, et al. In vitro assessment of PEEK and titanium implant abutments: screw loosening and microleakage evaluations under dynamic mechanical testing. J Prosthet Dent 2022;7(3):470–476. DOI: 10.1016/j.prosdent.2020.09.033
4. Matos JDM, Lopes GDRS, Queiroz DA, et al. Influence of the peek abutments on mechanical behavior of the internal connections single implant. Materials (Basel) 2022;15(22). DOI: 10.3390/ma15228133
5. Ragupathi M, Mahadevan V, Azhagarasan NS, et al. Comparative evaluation of the wear resistance of two different implant abutment materials after cyclic loading - an in vitro study. Contemp Clin Dent 2020;11(3):229–236. DOI: 10.4103/ccd.ccd_294_19
6. Milinkovic I, Krasavcevic AD, Jankovic S, et al. Immunohistochemical analysis of softtissue response to polyetheretherketone (PEEK) and titanium healing abutments on dentalimplants: a randomized pilot clinical study. BMC Oral Health 2022;22(1):484. DOI: 0.1186/s12903-022-02536-0
7. Ghazal-Maghras R, Vilaplana-Vivo J, Camacho-Alonso F, et al. Properties of polyetheretheretherketone (PEEK) implant abutments: a systematic review. J Clin Exp Dent 2022;14(4):e349–e358. DOI: 10.4317/jced.59466
________________________
© The Author(s). 2023 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.