RESEARCH ARTICLE


https://doi.org/10.5005/jp-journals-10019-1277
International Journal of Prosthodontics and Restorative Dentistry
Volume 10 | Issue 3 | Year 2020

Color Changes of Restorative Materials with Different Surface Finishing Processes Applied and Kept in Different Solutions


Alper Ozdogan1, Ozcan Akkal2, Zeynep Sen Yilmaz3

1–3Department of Prosthodontics, Faculty of Dentistry, University of Atatürk, Erzurum, Turkey

Corresponding Author: Alper Ozdogan, Department of Prosthodontics, Faculty of Dentistry, University of Atatürk, Erzurum, Turkey, Phone: +90 4422360942/1684, e-mail: alprozdgn@gmail.com

How to cite this article Ozdogan A, Akkal O, Sen Yilmaz Z. Color Changes of Restorative Materials with Different Surface Finishing Processes Applied and Kept in Different Solutions. Int J Prosthodont Restor Dent 2020;10(3):115–121.

Source of support: Nil

Conflict of interest: None

ABSTRACT

Aim: Investigation of color changes of restorative materials with different surface finishing processes applied and kept in different solutions.

Materials and methods: Totally 240 rectangular prism specimens were used in this study. Specimens were produced by four different restorative materials (two composites, lithium disilicate ceramic and zirconia) and each group was randomly divided into three groups. The three different surface finishing processes were applied to the specimens, and again, each group was randomly divided into four groups (n = 5). The initial color measurements were performed by spectrophotometer and recorded, after that the specimens were kept in four different solutions for a total of 28 days. The first 7- and 28-day color measurements of the specimens were made by spectrophotometer and recorded. Data were analyzed with Kruskal–Wallis and Tamhane’s T2 test.

Results: There was a statistically significant difference between the discolorations of the restorative materials (p %3C; 0.001) and was no statistical difference between the different polishing processes (p %3E; 0.05) during all periods. Although there was a statistically significant difference between the discolorations during 0–7 days and 7–28 days (p < 0.001), there was no statistically significant difference between the discolorations during 0–28 days (p > 0.05).

Conclusion: During 0–28 days of investigations, different solutions cause a color change in restorative materials, and surface polishing processes are of no importance in this case.

Keywords: Color, Composite, Lithium disilicate, Surface polishing, Zirconia..

INTRODUCTION

Nowadays, people’s greatest expectation regarding oral and dental health is esthetics. Therefore, restorative materials play a very significant role in dentistry clinical practices. Along with the development of technology, the esthetic properties of esthetic restorative materials have also improved. Composites, glass-ceramics, and zirconia restorations take up quite a large space in the esthetic procedure steps of prosthetic dental treatment.1 Composite resins first began to be used in dentistry in the 1960s, and nowadays, they have become commonly used in the anterior and posterior regions.2 Composites are esthetic filling materials consisting of organic, inorganic, and binding components that are bonded to tooth tissue by adhesion.3 Zirconia ceramics with superior mechanical properties began to be used in dentistry in the 1990s.4 Zirconia, which is a polymorphic material, is used as an alternative to metal framework systems due to its sufficient esthetic properties as well as its good mechanical properties.5 Nowadays, they are covered with a veneer restoration and are used as frameworks,6 and also they are preferred in the production of esthetic restorations monolithically.7 All-ceramic restorations are a group of materials with ever-increasing popularity due to their superior esthetic properties, biocompatibility, and corrosion-resistant structures.8 Glass-ceramics with lithium disilicate content are systems that show good adhesion to the tooth structure, have high flexural strength, and also allow for the production of monolithic restorations.911

Color is one of the most important parameters that affect the clinical durability of restoration as well as its esthetic character. The restorations applied are expected to be similar to natural teeth and to display a natural appearance. It is also expected that the restoration will maintain its color for a long time and will not lose its color by being affected by intraoral changes. Discolorations can be external or internal. External discolorations can occur due to poor oral hygiene, the effect of restorations, plaque build-up, dietary habits, and the presence of chromogenic microorganisms.12 Drinks, such as, tea, coffee, juice, coke, and wine, which are frequently consumed in daily life, can cause discoloration in teeth and restorations. Apart from these drinks, mouthwashes used as an antimicrobial agent can also cause dental discoloration.13

Objective and reliable measurement devices, such as, spectrophotometer and colorimeter, are used to evaluate the discoloration.14 In dentistry, the color properties of natural teeth and restorative materials can be measured using the Commission Internationale de l’Eclairage (CIE) color system.15 ΔE values in these measurements are evaluated as follows: ΔE < 3 is clinically undetectable, ΔE = 3–5 is clinically acceptable, and ΔE > 5 is clinically unacceptable.16

Additional adaptation procedures may be required before a restoration is placed in the mouth. In this case, there may be deterioration in the surface polish of the restoration. The polished surfaces of restorations must be reconstructed before they are cemented to the mouth. In such cases, the polishing process can be applied with polishing rubbers or kits at the chairside to regain the lost surface polish in restorations.17 For this purpose, different polishing kits have been offered for use by the manufacturers. Different systems including tungsten carbide finishing burs, diamond rotary instruments, silicone rubber disks, and silicon carbide or aluminum oxide-coated abrasive disks form the content of polishing kits.18

This study aims to investigate the discolorations of restorative materials that have been treated with different surface finishing processes and kept in different solutions. The hypotheses of the study are as follows: (i) the most discoloration will occur in composite specimens, (ii) differences in surface finishing processes will affect the discolorations of restorations, and (iii) different solutions and holding time in solutions will increase the discolorations of materials.

MATERIALS AND METHODS

Within the scope of the study, four restorative materials, three different polishing systems, and four different solutions were used. Information about the materials used in the study is presented in Table 1. A total of 240 rectangular prism specimens with the dimensions of 10 × 4 × 2 were prepared, consisting of 60 specimens of each restorative material. As a result of the power analysis conducted to determine the number of specimens, the G*Power software program (v.3.0.10) was used to obtain the highest power level with the smallest specimen size. The analysis showed that at least five specimens were required for the highest power level (power = 80, α = 0.05).

Table 1: The materials and solutions are used in the study
Material typeBrand nameManufacturer
Nano hybrid compositeGrandioVoco
Nano-filled compositeClear Majesty EstheticKuraray Noritake
Lithium disilicate glass ceramicIPS e.max PressIvoclar Vivadent
ZirconiumPrettau ZirconiaZirkonzahn
Glaze for lithium disilicateIPS e.max Press Ceram Glaze PasteIvoclar Vivadent
Glaze for zirconiaGlaze PlusZirkonzahn
Ceramic polishing kitLuster Intraoral Twist KitHager and Meisinger
Ceramic polishing kitOptraFine AssortmentIvoclar Vivadent
TeaLipton Earl GreyUnilever
CoffeeNescafe GoldNestle
CokeCoca ColaCoca Cola Comp.
MouthwashTantum VerdeAngelini

The color of the restorative materials was determined to be A1 according to the Vita scale, and the specimens were prepared according to the manufacturer’s instructions in line with their own production techniques. In the preparation of composite specimens, molds from silicone-based impression material (elite HD + putty soft; Zhermack, Badia Polesine, Italy) were prepared by the initial dimensions. Composite resins (Grandio, Clearfil Majesty Esthetic) were placed in silicone molds by the incremental technique and polymerized by an LED curing device Valo Grand (Valo; Ultradent, South Jordan, Utah, USA) for 20 seconds. After the obtained specimens were removed from the molds, marginal corrections and final finishing processes were performed using Soflex discs (Sof-Lex™; 3M ESPE, Maplewood, New Jersey, USA). The wax patterns (Elastiwac; Keram and Keramik) prepared for lithium disilicate specimens were taken into investment (IPS e.max Special Investment Material; Ivoclar Vivadent) and pre-heated at 850°C for 1 hour after the investment hardened. Following this heat treatment, IPS e.max Press ingots (Ivoclar Vivadent) were pressed at 920°C with a temperature increase rate of 60°C/minute in the EP 600 oven with the initial temperature of 700°C, after 25 minutes of holding time. Zirconia specimens were produced from Prettau blocks (Zirkonzahn GmbH, Gais, Italy) by engraving with the help of a CAD/CAM unit (Yenadent D40 CAM unit; Yenadent, ZenoTec, İstanbul, Turkey) with a thickness of 10 × 4 × 2 mm. The sintering process of the specimens in the sintering furnace (Zirkonofen, Gais, Italy) was performed as per the manufacturer’s instructions with the initial temperature of 300°C and the holding time of 30 minutes, the final temperature of 1540°C reached in 60 minutes, and the holding time of 90 minutes at 1540°C.

After measuring the dimensions of all the specimens obtained with the help of a digital micrometer and making sure that they were correct, the specimens in each group were randomly divided into three groups for polishing processes. The polishing processes applied to the specimen surfaces are as follows:

Conventional Polishing

The denture sealant agent (Palaseal; KulzerandCoGmbH, Wefirheim/Ts, Germany) was applied to the composite specimen surfaces and polymerized in the polymerization unit (HiLite Power; Heraeus Kulzer; Hanau, Germany) for 6 minutes. For the conventional polishing of lithium disilicate and zirconia specimens, the glaze materials specific to each material were fired by applying them in a thin layer.

Meisinger Polishing Kit

Polishing rubbers included in the kit were applied to the specimen surfaces according to the order (green–blue–red–yellow) in the manufacturer’s instructions. The rotating speed of the handpiece was applied by the same researcher in the form of circular movements for each polishing rubber for 60 seconds, with a maximum of 10,000 rpm and an average pressure of 2 N and without water cooling, according to the manufacturer’s instructions.

OptraFine Polishing Kit

Polishing rubbers included in the kit were applied to the specimen surfaces according to the order (light blue–dark blue) in the manufacturer’s instructions. The rotating speed of the handpiece was applied by the same researcher in the form of circular movements for each polishing rubber for 60 seconds, with a maximum of 10,000 rpm, water cooling, and an average pressure of 2 N, according to the manufacturer’s instructions. Then, the polishing paste (OptraFine HP PolishingPaste; Ivoclar Vivadent AG) in the kit was applied to the specimen surfaces with the same handpiece speed and pressure, this time without water cooling, for 60 seconds and in the form of circular movements.

The specimens, of which surface polishing was completed, were numbered, and the initial color measurements were performed by a single researcher with the help of a spectrophotometer (VITA EasyShade V; VITA Zahnfabrik, Bad Sackingen, Germany), with the background in a gray tone.19 All measurements of the specimens placed in the background were performed in the “single tooth” mode of the spectrophotometer. Three measurements were made on the gray background from the right, left, and middle regions of each specimen and averaged. Before each measurement, the spectrophotometer was calibrated according to the manufacturer’s recommendations. The color values of all specimens were recorded according to the CIE L*a*b* system. With the formula ∆E* = [(∆L*)2 + (∆a*)2 + (∆b*)2]1/2, the mean value of each specimen was obtained20 and recorded as ∆E(0). The specimens, of which color measurements were completed, were randomly divided into four groups (n = 5) and kept in four different solutions in a dark, closed environment and at room temperature for 7 and 28 days. The solutions were replaced every day to ensure standardization. After 7 days, the specimens were removed from the solutions, washed, and dried. The color measurements of the specimens were performed by the first measurement protocol, and the color value of each specimen was recorded as ∆E(7). The specimens, of which measurements were completed, were placed in the solutions again, and at the end of the 28th day, color measurements were performed according to the initial protocol by removing them from the solutions, and the ∆E value of each specimen was recorded as ∆E(28).

Statistical analysis of the data was conducted with the Kolmogorov–Smirnov homogeneity test and Kruskal–Wallis test using the IBM v.20 packaged software (SPSS v.20.0; SPSS Inc., Chicago, Illinois, USA). Tamhane’s T2 multiple comparison tests was used for intergroup comparisons.

RESULTS

According to the data obtained from the results of the Kruskal–Wallis test (Table 2):

It was observed that there was a statistically significant difference between the discolorations of the restorative materials during 0 to 7, 7 to 28, and 0 to 28 days (p %3C; 0.001), and there was no statistical difference between the discolorations related to different polishing processes during 0 to 7, 7 to 28, and 0 to 28 days (p %3E; 0.05). In the comparison of the solutions in which they were kept, although there was a statistically significant difference between the discolorations during 0 to 7 and 7 to 28 days (p < 0.001), there was no statistically significant difference between the discolorations during 0 to 28 days (p > 0.05). The mean, standard deviation values, and Tamhane’s T2 multiple comparison test results of the groups are shown in Tables 3 to 5. The 0 to 7, 7 to 28, and 0 to 28 days color changes of the materials polishing methods and solutions used in the study are shown in Figures 1 to 3.

Table 2: Kruskal–Wallis test results of the groups
Groups0–7 days0–28 days7–28 days
Restorative materialsChi-square81.408136.59060.010
df  3  3  3
Asymp. Sig.  0.000  0.000  0.000
Polishing proceduresChi-square  0.221  0.457  0.308
df  2  2  2
Asymp. Sig.  0.896  0.796  0.857
SolutionsChi-square11.890  5.68329.126
df  3  3  3
Asymp. Sig.  0.008  0.128  0.000
Table 3: 0 to 7 days mean ∆E values and Tamhane’s T2 multiple comparison test results for groups
Material0–7 days
N
MeanStd. Dev.
Grandio3.99a2.0260
Clearfil Majesty Esthetic3.95a2.1060
IPS e.max Press0.96b0.5660
Prettau Zirconia0.11c0.0260
Conventional3.062.1380
Meisinger1.250.9680
OptraFine1.541.2980
Tea0.32A0.7260
Coffee1.19A,B1.5260
Coca Cola1.89B1.0560
Mouthwash2.39B3.2060

a–c Mean significantly different for restorative materials; A,BMean significantly different for solutions (p %3C; 0.05)

Table 4: 7 to 28 days mean ∆E values and Tamhane’s T2 multiple comparison test results for groups
Material7–28 days
N
MeanStd. Dev.
Grandio5.98a1.7860
Clearfil Majesty Esthetic5.02a2.4460
IPS e.max Press1.54b1.3460
Prettau Zirconia0.56c0.5460
Conventional0.230.5580
Meisinger1.381.1480
OptraFine1.571.3380
Tea2.58A1.6960
Coffee2.01A1.5160
Coca Cola1.25B0.6560
Mouthwash2.76A1.4460

a–c Mean significantly different for restorative materials; A,BMean significantly different for solutions (p < 0.05)

Table 5: 0 to 28 days mean ∆E values and Tamhane’s T2 multiple comparison test results for groups
Material0–28 days
N
MeanStd. Dev.
Grandio6.04a4.0160
Clearfil Majesty Esthetic7.15a4.8260
IPS e.max Press1.53b0.8060
Prettau Zirconia0.56b0.4360
Conventional2.821.8380
Meisinger2.722.1280
OptraFine3.442.8880
Tea3.413.1660
Coffee3.282.4760
Coca Cola1.611.1360
Mouthwash2.692.9260

a,b Mean significantly different for restorative materials (p < 0.05)

Fig. 1: Graph showing the color changes of the restorative materials at 0 to 7, 7 to 28, and 0 to 28 days

Fig. 2: Graph showing the color changes of the polishing methods at 0 to 7, 7 to 28, and 0 to 28 days

Fig. 3: Graph showing the color changes of the solutions at 0 to 7, 7 to 28, and 0 to 28 days

When the discolorations between 0 and 7 days belonging to the groups were examined according to Tamhane’s T2 multiple comparison test results:

It was observed that the most discoloration occurred in Grandio composite and then in Clearfil composite and the difference between them was not statistically significant (p %3E; 0.05), the least discoloration occurred in Prettau zirconia, IPS e.max Press had more discoloration than Prettau zirconia, and there was a difference between them and composites (p < 0.001). When the solutions in which they were kept were evaluated, it was observed that the least discoloration occurred in the specimens kept in tea and they showed a statistically significant difference with other solutions except for coffee (p < 0.05), the most discoloration occurred in the specimens kept in the mouthwash, they were followed by the specimens kept in coke and coffee, respectively, and the difference between them was not statistically significant (p > 0.05).

When the discolorations between 7 and 28 days belonging to the groups were examined according to Tamhane’s T2 multiple comparison test results:

It was observed that the most discoloration occurred in Grandio composite as in the discolorations between 0 and 7 days and then in Clearfil composite and the difference between them was not statistically significant (p > 0.05), the least discoloration occurred in Prettau zirconia, IPS e.max Press had more discoloration than Prettau zirconia, and there was a difference between them and composites (p < 0.001). When the solutions in which they were kept were evaluated, it was observed that the most discoloration occurred in the specimens kept in the mouthwash, they were followed by the specimens kept in tea and coffee, respectively, the difference between them was not statistically significant (p > 0.05), and the least discoloration occurred in the specimens kept in coke, and they showed a statistically significant difference with all other solutions (p < 0.05).

When the discolorations between 0 and 28 days belonging to the groups were examined according to Tamhane’s T2 multiple comparison test results:

It was observed that the most discoloration occurred this time in Clearfil composite and then in Grandio composite, and the difference between them was not statistically significant (p > 0.05). It was observed that the least discoloration occurred in Prettau Zirconia specimens, and they were followed by IPS e.max Press specimens. Although the difference between them was not statistically significant (p > 0.05), they showed a significant difference with composite specimens (p < 0.001). It was found that there was no statistically significant difference in the discolorations during 0 to 28 days between polishing processes and solutions in which the specimens were kept (p > 0.05).

According to the Wilcoxon test results conducted to examine the relationship between the discolorations according to the days, it was concluded that:

DISCUSSION

This study aimed to investigate the discolorations of restorative materials that have been treated with different surface finishing processes and kept in different solutions for different periods. As a result of the study, our first hypothesis was accepted since most discoloration occurred in composite specimens. However, other hypotheses were rejected because different surface finishing processes did not affect the discoloration statistically, and although there were differences between the discolorations of the groups during 0 to 7 and 7 to 28 days, there was no statistically difference between the discolorations during 0 to 28 days and all solutions in which they were kept.

Numerous factors, such as, dehydration, water absorption, surface roughness, and colored peroxide compounds formed as a result of the oxidation of carbon–carbon double bonds are effective in the discoloration of esthetic restorative materials.21 The discoloration of restorative materials may vary depending on the patient’s eating habits, the drinks consumed and the frequency of consumption, oral hygiene care, and the structure of the materials. The discoloration occurs as a result of the color pigments in food taken with diet discoloring the surface, or the pigments diffusing together with the liquid into the framework material and between the molecules.22 The limit value of the color difference noticeable by the human eye or the acceptable color difference was determined as different values as a result of different studies. The acceptable values were specified as between ΔE = 1, ΔE = 2, ΔE = 3, ΔE > 3.3 or ΔE = 3.3 and ΔE > 3.7 or ΔE = 3.7.23 On the one hand, Seghi et al.24 reported that the mean acceptable color difference value should be ΔE > 2. Yannikakis et al.,25 on the other hand, stated that values below ΔE = 3.7 are “acceptable” and values above that are “unacceptable”. Most of the studies on this subject were carried out in vitro. In their in vivo study, Johnston and Kao26 found that ΔE value should be below 3.7 for an optimal color match within the mouth. In this study, it was observed that discolorations in all the groups evaluated during 0 to 7 days were acceptable or close to acceptable, and in longer evaluations, only composite specimens had a discoloration above the acceptable level. This situation is in line with the data in the literature.

According to Ertas et al.,27 the maximum holding time of the materials in solutions is 4 weeks. This period is equivalent to 2.5 years of use. In their study, Crispin and Caputo28 reported that tea and coffee solutions caused high discoloration after 1 month. For this reason, we limited our study to 28 days. Furthermore, since composite resins are reported to have a significant discoloration within the first 7 days,28,29 the measurement of 7-day values was also included in the study.

Studies on discolorations of many restorative materials are available in the literature. In a study on the discolorations of different composite resins, it was reported that the solutions in which they were kept affected the discoloration of materials, the most discoloration occurred in the specimens kept in red wine, the discoloration in mouthwashes was acceptable, and dual-polymerized resins had the highest discoloration values.30 In another study conducted with composite resins, the 7-day evaluation showed that the most discoloration occurred in red wine, then in tea and coffee. Moreover, specimens kept in coke and water were reported to have the least discoloration.31 In another study, it was observed that grape juice caused the discoloration in composite specimens within 1 week, while coffee and yerba mate did not cause any discoloration.32

In a study on discolorations of lithium disilicate ceramics, it was reported that the most discoloration occurred in the specimens kept in coke and orange juice, and coffee caused the highest opacity and lowest translucency in the specimens.33 It was reported that the discoloration created by the coffee thermal cycle applied to zirconia-reinforced ceramics and lithium disilicate ceramics was acceptable.34 Another study reported that the coffee thermal cycle caused the discoloration in monolithic and veneer zirconia, but these discolorations were also at clinically acceptable levels.35 In a study on zirconia ceramics, it was reported that the materials were not affected by acidic drinks, although their ∆E values were affected by coffee.36 According to the results of this study, when the discolorations during 0 to 7 days were examined, it was observed that the most discoloration occurred in the Grandio composite, and the least discoloration occurred in Prettau zirconia. When the discolorations during 7 to 28 days belonging to the groups were examined, it was observed that the most discoloration occurred in Grandio composite, and the least discoloration occurred in Prettau zirconia. When the discolorations during 0 to 28 days belonging to the groups were examined, it was observed that the most discoloration occurred in Clearfil composite this time, and the least discoloration occurred in Prettau Zirconia specimens. It is thought that the discoloration occurred at a higher level in composite specimens than the other materials compared due to the internal structure of the materials, their surface properties, and higher liquid absorption.

In their study, Guler et al.37 reported that drinks causing the most discoloration in various restorative materials were red wine, coffee, coffee with the milk powder, and tea with sugar, respectively. In various studies in which the coloring effect of coke was tested, it was thought to have low pH due to the citric acid in its content and cause the matrix to soften, leading to deterioration in the composite surfaces, and high ΔE values were expected.28,38 In studies related to mouthwashes, Baig et al.39 stated that Listerine caused less discoloration in nanocomposites than non-alcohol chlorhexidine, Soygun et al.40 stated that mouthwashes with high alcohol content increased the discoloration of bioceramics, and Derafshi et al.,41 on the other hand, stated that the discolorations of monolithic zirconia and feldspathic porcelain in Listerine and chlorhexidine were clinically acceptable. Although there was a statistical difference between the discolorations during 0 to 7 and 7 to 28 days in the comparison of the solutions in which they were kept according to the results of this study, there was no statistically significant difference between the discolorations during 0 to 28 days. It was observed that the most discoloration was in the mouthwash and the least discoloration was in tea during 0 to 7 days, and the most discoloration was in the mouthwash and the least discoloration was in coke during 7 to 28 days. On the other hand, there was no significant difference between solutions during 0 to 28 days. It is considered that the different results acquired in three different time periods were caused by factors, such as, the temperature of the solutions in which the specimens were kept, the room temperature, or the darkness of the holding environment.

While it was expected that different polishing processes would create a significant difference in the discoloration of restorative materials in the study, no statistical difference was found between different polishing processes during 0 to 7, 7 to 28, and 0 to 28 days. It is assumed that this is because different polishing processes have a similar effect on the surfaces of materials, or the polishing process affects only the outer surface of the material.

One of the limitations of the study is that the surface roughness of the materials was not evaluated while polishing the materials. Thus, the relationship between surface roughness and discoloration was not evaluated. Another limitation is that the study is an in vitro study, so it cannot fully reflect oral conditions.

CONCLUSION

Within the limits of this study, the following conclusions were reached:

REFERENCES

1. Sakaguchi R, Ferrance J, Powers J. Craig’s Restorative Dental Materials.St. Louis, Missouri: Elsevier; 2019. pp. 209–210.

2. Hickel R, Dasch W, Janda R, et al. New direct restorative materials. FDI commission project. Int Dent J 1998;48(1):3–16. DOI: 10.1111/j.1875-595X.1998.tb00688.x.

3. Jackson RD, Morgan M. The new posterior resins and a simplified placement technique. J Am Dent 2000;131(3):375–383. DOI: 10.14219/jada.archive.2000.0182.

4. Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials 1999;20(1):1–25. DOI: 10.1016/S0142-9612(98)00010-6.

5. Koçak EF, Uçar Y, Kurtoğlu C, et al. Color and translucency of zirconia infrastructures and porcelain-layered systems. J Prosthet Dent 2019;121(3):510–516. DOI: 10.1016/j.prosdent.2018.08.001.

6. Prasad HA, Pasha N, Hilal M, et al. To evaluate effect of airborne particle abrasion using different abrasives particles and compare two commercial available zirconia on flexural strength on heat treatment. Int J Biomed Sci 2017;13(2):93–112.

7. Marchack BW, Sato S, Marchack CB, et al. Complete and partial contour zirconia designs for crowns and fixed dental prostheses: a clinical report. J Prosthet Dent 2011;106(3):145–152. DOI: 10.1016/S0022-3913(11)60112-1.

8. Castellani D, Baccetti T, Giovannoni A, et al. Resistance to fracture of metal ceramic and all-ceramic crowns. Int J Prosthodont 1994;7(2):149–154.

9. Bakeman EM, Rego N, Chaiyabutr Y, et al. Influence of ceramic thickness and ceramic materials on fracture resistance of posterior partial coverage restorations. Oper Dent 2015;40(2):211–217. DOI: 10.2341/12-459-L.

10. Raptis NV, Michalakis KX, Hirayama H. Optical behavior of current ceramic systems. Int J Periondont Resto Dent 2006;26(1):31–41.

11. Schwarz S, Schroder C, Hassel A, et al. Survival and chipping of zirconia-based and metal-ceramic implant-supported single crowns. Clin Implant Dent Relat Res 2012;14(S1):e119–e125. DOI: 10.1111/j.1708-8208.2011.00388.x.

12. Aschheim KW, Dale BG, Esthetic. Dentistry: A Clinical Approach to Techniques and Materials.St. Louis: Mosby; 2001. pp. 1–606.

13. Celik C, Yuzugullu B, Erkut S, et al. Effects of mouth rinses on color stability of resin composites. Eur J Dent 2008;2(4):247–253. DOI: 10.1055/s-0039-1697388.

14. Khokhar ZA, Razzoog ME, Yaman P. Color stability of restorative resins. Quintessence Int 1991;22(9):733–737.

15. Nogueira AD, Della, Bona A. The effect of a coupling medium on color and translucency of CAD-CAM ceramics. J Dent 2013;41(S3):e18–e23. DOI: 10.1016/j.jdent.2013.02.005.

16. Alghazali N, Burnside G, Moallem M, et al. Assessment of perceptibility and acceptability of color difference of denture teeth. J Dent 2012;40(S1):e10–e17. DOI: 10.1016/j.jdent.2012.04.023.

17. Martinez-Gomis J, Bizar J, Anglada JM, et al. Comparative evaluation of four finishing systems on one ceramic surface. Int J Prosthodont 2003;16(1):74–77.

18. Jefferies SR. The art and science of abrasive finishing and polishing in restorative dentistry. Dent Clin North Am 1998;42(4):613–627.

19. Shokry TE, Shen C, Elhosary MM, et al. Effect of core and veneer thicknesses on the color parameters of two all-ceramic systems. J Prosthet Dent 2006;95(2):124–129. DOI: 10.1016/j.prosdent.2005.12.001.

20. Knispel G. Factors affecting the process of color matching restorative materials to natural teeth. Quintessence Int 1991;22(7):525–531.

21. Anıl N, Hekimoğlu C, Şahin S. Color stability of heat-polymerized and autopolymerized soft denture liners. J Prosthet Dent 1999;81(4):481–484. DOI: 10.1016/S0022-3913(99)80018-3.

22. Takabayashi Y. Characteristics of denture thermoplastic resins for non-metal clasp dentures. Dent Mater J 2010;29(4):353–361. DOI: 10.4012/dmj.2009-114.

23. Sham AS, Chu FC, Chai J, et al. Color stability of provisional prosthodontic materials. J Proshet Dent 2004;91(5):447–452.

24. Seghi RR, Hewlett ER, Kim J. Visual and instrumental colorimetric assessments of small color differences on translucent dental porcelain. J Dent Res 1989;68(12):1760–1764. DOI: 10.1177/00220345890680120801.

25. Yannikakis SA, Zissis AJ, Polyzois GL, et al. Color stability of provisional resin restorative materials. J Proshet Dent 1998;80(5):533–539.

26. Johnston WM, Kao EC. Assessment of appearance match by visual observation and clinical colorimetry. J Dent Res 1989;68(5):819–822. DOI: 10.1177/00220345890680051301.

27. Ertas E, Guler AU, Yucel AC, et al. Color stability of resin composites after immersion in different drinks. Dent Mater J 2006;25(2):371–376. DOI: 10.4012/dmj.25.371.

28. Crispin BJ, Caputo AA. Color stability of temporary restorative materials. J Dent Res 1979;42(1):27–33. DOI: 10.1016/0022-3913(79)90326-3.

29. Arocha MA, Basilio J, Llopis J, et al. Colour stainability of indirect CAD-CAM processed composites vs. Conventionally laboratory processed composites after immersion in staining solutions. J Dent 2014;42(7):831–838. DOI: 10.1016/j.jdent.2014.04.002.

30. Falkensammer F, Arnetzl GV, Wildburger A, et al. Color stability of different composite resin materials. J Proshet Dent 2013;109(6):378–383.

31. Quek SHQ, Yap AUJ, Rosa V, et al. Effect of staining beverages on color and translucency of CAD/CAM composites. J Esthet Restor Dent 2018;30(2):E9–E17. DOI: 10.1111/jerd.12359.

32. Fontes ST, Fernández MR, Moura CMD, et al. Color stability of a nanofill composite: Effect of different immersion media. J Appl Oral Sci 2009;17(5):388–391. DOI: 10.1590/S1678-77572009000500007.

33. Dos Santos DM, da Silva EVF, Watanabe D, et al. Effect of different acidic solutions on the optical behavior of lithium disilicate ceramics. J Proshet Dent 2017;118(3):430–436. DOI: 10.1016/j.prosdent.2016.10.023.

34. Alp G, Subasi MG, Johnston WM, et al. Effect of surface treatments and coffee thermocycling on the color and translucency of CAD-CAM monolithic glass-ceramic. J Proshet Dent 2018;120(2):263–268.

35. Subasi MG, Alp G, Johnston WM, et al. Effects of fabrication and shading technique on the color and translucency of new-generation translucent zirconia after coffee thermocycling. J Proshet Dent 2018;120(4):603–608. DOI: 10.1016/j.prosdent.2018.01.018.

36. Colombo M, Cavallo M, Miegge M, et al. Color stability of CAD/CAM zirconia ceramics following exposure to acidic and staining drinks. J Clin Exp Dent 2017;9(11):e1297–e1303. DOI: 10.4317/jced.54404.

37. Guler A, Yilmaz F, Kulunk T, et al. Effects of different drinks on stainability of resin composite provisional restorative materials. J Prosthet Dent 2005;94(2):118–124. DOI: 10.1016/j.prosdent.2005.05.004.

38. Nasim I, Neelakantan P, Sujeer R, et al. Color stability of microfilled, microhybrid and nanocomposite resins--an in vitro study. J Dent 2010;38(S2):e137–e142. DOI: 10.1016/j.jdent.2010.05.020.

39. Baig AR, Shori DD, Shenoi PR, et al. Mouthrinses affect color stability of composite. J Conserv Dent 2016;19(4):355–359. DOI: 10.4103/0972-0707.186448.

40. Soygun K, Varol O, Ozer A, et al. Investigations on the effects of mouthrinses on the colour stability and surface roughness of different dental bioceramics. J Adv Prosthodont 2017;9(3):200–207. DOI: 10.4047/jap.2017.9.3.200.

41. Derafshi R, Khorshidi H, Kalantari M, et al. Effect of mouthrinses on color stability of monolithic zirconia and feldspathic ceramic: an in vitro study. BMC Oral Health 2017;17(1):129. DOI: 10.1186/s12903-017-0419-9.

________________________
© The Author(s). 2020 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.