Citation Information :
Mopkar M, Mascarenhas K. Prosthetic Rehabilitation of an acquired Ocular Defect in a Pediatric Patient: A Clinical Report. Int J Prosthodont Restor Dent 2018; 8 (2):63-67.
The eye is one of the vital sense organs. Apart from being a physical disability, the psychological impact can be quite traumatic. The early cosmetic restoration of acquired defects boosts the patient's confidence and enhances maintenance of tissue health. The following article describes a technique to customize a prosthesis in a patient of the pediatric age group. Such a fabricated prosthesis adapts better than prefabricated stock prosthesis and the accurate positioning of the iris disk enhances the esthetic outcome.
Brown KE. Fabrication of an ocular prosthesis. J Prosthet Dent 1970 Aug;24(2):225-235.
Cain JR. Custom ocular prosthetics. J Prosthet Dent 1982 Dec;48(6):690-694.
McArthur RD. Aids for positioning prosthetic eyes in orbital prosthesis. J Prosthet Dent 1977 Mar;37(3):320-326.
Guttal SS, Patil NP, Vernekar N, Porwal A. A simple method of positioning the iris disk on a custom-made ocular prosthesis. A clinical report. J Prosthodont 2008 Apr;17(3): 223-227.
Hang PS, Andres JC. Fabrication of custom ocular prosthesis. In: Taylor DT, editor. Clinical maxillofacial prosthetics. Chicago (IL): Quintessence; 2000. pp. 265-275.
Da Costa GC, Aras MA, Chalakkal P, Da Costa MC. Ocular prosthesis incorporating IPS e-max press scleral veneer and a literature review on non-integrated ocular prosthesis. Int J Ophthalmol 2017 Jan;10(1):148-156.
Taicher S, Steinberg HM, Tubiana I, Sela M. Modified stockeye ocular prosthesis. J Prosthet Dent 1985 Jul;54(1):95-98.
Kulkarni RS, Kulkarni P, Shah RJ, Tomar B. Aesthetically characterized ocular prosthesis. J Coll Physicians Surg Pak 2018 Jun;28(6):476-478.
Alfenas ER, da Silva JG, Silveira ME, Fonseca MF, de Arruda JA, Moreno A. A painting technique using ceramic pigments for the artificial iris of an ocular prosthesis guided by applying Newton's color wheel. J Prosthodont 2018 Jun 13.
Yago K, Furuta M. Orbital growth after unilateral enucleation in infancy without an orbital implant. Jpn J Ophthalmol 2001 Nov-Dec;45(6):648-652.
Bartlett SO, Moore DJ. Ocular prosthesis: a physiologic system. J Prosthet Dent 1973 Apr;29(4):450-459.
Raizada D, Raizada K, Naik M, Murthy R, Bhaduri A, Honavar SG. Custom ocular prosthesis in children: how often is a change required? Orbit 2011 Oct;30(5):208-213.
Parr GR, Goldman BM, Rahn AO. Postinsertion care of the ocular prosthesis. J Prosthet Dent 1983 Feb;49(2):220-224.
Litwin AS, Worrell E, Roos JC, Edwards B, Malhotra R. Can we improve the tolerance of an ocular prosthesis by enhancing its surface finish? Ophthalmic Plast Reconstr Surg 2018 Mar;34(2):130-135.