Citation Information :
Alaa S, Loubna EF, Sara M, Amal EY. The Success Rate of Resin-bonded Fixed Partial Dentures Replacing Maxillary Central Incisor: A Systematic Review. Int J Prosthodont Restor Dent 2025; 15 (1):51-59.
Purpose: The purpose of this systematic review was to evaluate the success rate of resin-bonded fixed dental prostheses (RBFDPs) replacing the maxillary central incisor (MCI).
Materials and methods: A systematic and manual search was performed in the PubMed, Scopus, and Cochrane Central Register of Controlled Trials (CENTRAL) databases. The prospective (PCS) and retrospective (RCS) cohort studies, as well as randomized controlled trials (RCTs) with an observation time of at least 2.5 years and providing quantitative clinical results on RBFDPs replacing MCI, were included. The focused question was, “Can absence of the maxillary central incisor be effectively treated by RBFDPs?” The Newcastle-Ottawa scale was used to assess the quality of the included cohort studies. However, the quality of the RCTs was assessed with version 2 of the Cochrane risk-of-bias tool (RoB 2).
Results: Among 1,037 screened articles, four PCS and a single RCT were included in this review. All the RBFDPs replacing MCI evaluated in our studies were made of metal-ceramic material. The annual success rate of RBFDPs replacing MCI, calculated for each study, ranged from 88.3 to 97.3%. Of the 90 RBFDPs replacing MCI reported in the included studies, debonding was the most common complication of these restorations, with a relatively high rate (88%). The biological complications reported in this review were caries and periodontal pockets, with percentages of 8 and 4%, respectively. No meta-analysis was performed given the limited overall sample.
Conclusion: Based on this study, the literature did not provide strong evidence to support or reject the reliability of RBFDPs for MCI replacement. Most of the included studies were PCS, and all included studies were judged to be of low quality with a high risk of bias. No study has evaluated all-ceramic RBFDPs, which currently represent the evolution in the setting of minimally invasive restorations. Additional and more in-depth investigations through well-designed RCTs are necessary to obtain more reliable and solid results.
El-Kholey KE, Ramasamy S, Alaslani HH, et al. Dentist dilemmas on replacing single missing teeth: implant versus fixed partial denture – a survey among practicing dentists. Asian J Pharm Clin Res 2024;16:172–177. DOI: 10.4103/ajprhc.ajprhc-15-24
Qureshi S, Khan MWU, Akram M, et al. Restoration of missing central incisor with cantilevered zirconia resin-bonded fixed dental prosthesis. J Pak Dent Assoc Karachi 2022;31(4):194–197. DOI: 10.25301/JPDA.314.194
Bawa A, Johansen CS, Jensen SS, et al. Resin-bonded fixed dental prosthesis versus implant-supported single crowns in the anterior region. Clin Implant Dent Relat Res 2023;25:1197–1206. DOI: 10.1111/cid.13266
Rochette AL. Attachment of a splint to enamel of lower anterior teeth. J Prosthet Dent 1973;30:418–423. DOI: 10.1016/0022-3913(73)90163-7
Livaditis GJ, Thompson VP. Etched castings: an improved retentive mechanism for resin-bonded retainers. J Prosthet Dent 1982;47:52–58. DOI: 10.1016/0022-3913(82)90242-6
Shimizu H, Kawaguchi T, Takahashi Y. The current status of the design of resin-bonded fixed partial dentures, splints, and overcastings. Jpn Dent Sci Rev 2014;50:23–28. DOI: 10.1016/j.jdsr.2013.10.003
Weng D, Ries S, Richter EJ. Treatment of a juvenile patient with a maxillary all-ceramic resin-bonded fixed partial denture: a case report. Quintessence Int 2002;33:584–588.
Kelly JR, Benetti P. Ceramic materials in dentistry: historical evolution and current practice. Aust Dent J 2011;56:84–96. DOI: 10.1111/j.1834-7819.2010.01299.x
Jonker OA, Tirlet G, Dagba A, et al. A 32-month evaluation of lithium disilicate cantilever resin-bonded fixed dental prostheses to replace a missing maxillary incisor. J Prosthet Dent 2024;132:956–963. DOI: 10.1016/j.prosdent.2023.07.040
Türp L, Schlothauer T, Yazigi C, et al. Soft tissue changes at the pontic sites of cantilever zirconia ceramic resin-bonded fixed dental prostheses in the esthetic zone: a clinical observational study. J Esthet Restor Dent 2024;0:1–8. DOI: 10.1111/jerd.13350
Bömicke W, Haas J, Awounvo S, et al. Prospective clinical study of enamel wear caused by monolithic zirconia resin-bonded inlay-retained and wing-retained fixed partial dentures over 5 years. Clin Oral Investig 2024;29:15. DOI: 10.1007/s00784-024-06103-5
Wei YR, Wang XD, Zhang Q, et al. Clinical performance of anterior resin-bonded fixed dental prostheses with different framework designs: a systematic review and meta-analysis. J Dent 2016;47:1–7. DOI: 10.1016/j.jdent.2016.02.003
Mendes JM, Bentata ALG, De Sà J, et al. Survival rates of anterior-region resin-bonded fixed dental prostheses: an integrative review. Eur J Dent 2021;15:788–797. DOI: 10.1055/s-0041-1731587
Mourshed B, Samran A, Alfagih A, et al. Anterior cantilever resin-bonded fixed dental prostheses: a review of the literature. J Prosthodont 2016;27:266–275. DOI: 10.1111/jopr.12555
Chen J, Cai H, Ren X, et al. A systematic review of the survival and complication rates of all-ceramic resin-bonded fixed dental prostheses. J Prosthodont 2017;27:535–543. DOI: 10.1111/jopr.12678
Alqutaibi AY, Alghauli MA, Almuzaini SA, et al. Failure and complication rates of different materials, designs, and bonding techniques of ceramic cantilever resin-bonded fixed dental prostheses for restoring missing anterior teeth: a systematic review and meta-analysis. J Esthet Restor Dent 2024;36:1396–1411. DOI: 10.1111/jerd.13238
Al-Bermani ASA, Quigley NP, Ha WN. Do zirconia single-retainer resin-bonded fixed dental prostheses present a viable treatment option for the replacement of missing anterior teeth? A systematic review and meta-analysis. J Prosthet Dent 2023;130:533–542. DOI: 10.1016/j.prosdent.2021.10.015
Briggs P, Dunne S, Bishop K. The single-unit, single-retainer, cantilever resin-bonded bridge. Br Dent J 1996;181:373–379. DOI: 10.1038/sj.bdj.4809263
Kern M, Passia N, Sasse M, et al. Ten-year outcome of zirconia ceramic cantilever resin-bonded fixed dental prostheses and the influence of the reasons for missing incisors. J Dent 2017;65:51–55. DOI: 10.1016/j.jdent.2017.07.003
Page MJ, McKenzie JE, Bossuyt PM, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. J Clin Epidemiol 2021;134:178–189. DOI: 10.1016/j.jclinepi.2021.03.001
Samadi A, El Figuigui L, El Yamani A. The success rate of resin-bonded fixed partial dentures replacing maxillary central incisor: a systematic review. PROSPERO 2023. CRD42023479048. Available from: https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42023479048
Eriksen MB, Frandsen TF. The impact of patient, intervention, comparison, outcome (PICO) as a search strategy tool on literature search quality: a systematic review. J Med Libr Assoc 2018;106:420–431. DOI: 10.5195/jmla.2018.345
Antoine JY, Villaneau J, Lefeuvre A. Weighted Krippendorff's alpha is a more reliable metric for multi-coder ordinal annotations: experimental studies on emotion, opinion, and coreference annotation. Proc 14th Conf Eur Chapter Assoc Comput Linguist 2014;550–559.
Stang A. Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. Eur J Epidemiol 2010;25:603–605. DOI: 10.1007/s10654-010-9491-z
Higgins J, Savović J, Page MJ, et al. RoB 2: A revised Cochrane risk-of-bias tool for randomized trials. Br Med J 2019;1–24. DOI: 10.1136/bmj. l4898
Ott RL, Longnecker M. An introduction to statistical methods and data analysis. 7th ed. Boston: Cengage Learning; 2016.
Gotfredsen K, Alyass NS, Hagen MM. A 5-year randomized clinical trial on 3-unit fiber-reinforced versus 3- or 2-unit metal-ceramic resin-bonded fixed dental prostheses. Int J Prosthodont 2021;34:703–711. DOI: 10.11607/ijp.7090
Qiu HY, Wu SY, Fu L. Clinical performance of cantilevered resin-bonded fixed partial dentures for single tooth replacement in elderly patients. J Int Med Res 2020;48:1–6. DOI: 10.1177/0300060520956810
Botelho MG, Chan AWK, Leung NCH, et al. Long-term evaluation of cantilevered versus fixed-fixed resin-bonded fixed partial dentures for missing maxillary incisors. J Dent 2016;45:59–66. DOI: 10.1016/j.jdent.2015.12.006
Chan AW, Barnes IE. A prospective study of cantilever resin-bonded bridges: an initial report. Aust Dent J 2000;45:31–36. DOI: 10.1111/j.1834-7819.2000.tb00239.x
Hussey DL, Linden GJ. The clinical performance of cantilevered resin-bonded bridgework. J Dent 1996;24:251–256. DOI: 10.1016/0300-5712(95)00073-9
Keshtgar S, Crawford E, Hemmings KW, et al. Multidisciplinary management of missing maxillary central incisors in children and adolescents. Br Dent J 2023;234:661–667. DOI: 10.1038/s41415-023-5682-3
Campbell SD, Cooper L, Craddock H, et al. Removable partial dentures: the clinical need for innovation. J Prosthet Dent 2017;117:273–280. DOI: 10.1016/j.prosdent.2017.01.008
Botelho M. Resin-bonded prostheses: the current state of development. Quintessence Int 1999;30:525–535.
Durey KA, Nixon PJ, Robinson S, et al. Resin-bonded bridges: techniques for success. Br Dent J 2011;211:113–118. DOI: 10.1038/sj.bdj.2011.619
Balasubramaniam GR. Predictability of resin-bonded bridges – a systematic review. Br Dent J 2017;222:849–858. DOI: 10.1038/sj.bdj.2017.497
Alresheedi BA. All-ceramic resin-bonded fixed denture prostheses survival and complication rates: a review. Int J Dent Sci Clin Res 2020;8:143–149. DOI: 10.12691/ijdsr-8-6-1
Kern M. Clinical long-term survival of two-retainer and single-retainer all-ceramic resin-bonded fixed partial dentures. Quintessence Int 2005;36:141–147.
Klink A, Hüttig F. Zirconia-based anterior resin-bonded single-retainer cantilever fixed dental prostheses: a 15- to 61-month follow-up. Int J Prosthodont 2016;29:284–286. DOI: 10.11607/ijp.4220
Zitzmann NU, Büren AV, Glenz F, et al. Clinical outcome of metal- and all-ceramic resin-bonded fixed dental prostheses. J Prosthodont Res 2021;65:243–248. DOI: 10.2186/jpr.JPR_D_20_00014
Saker S, El-Fallal A, Abo-Madina M, et al. Clinical survival of anterior metal-ceramic and all-ceramic cantilever resin-bonded fixed dental prostheses over a period of 60 months. Int J Prosthodont 2014;27:422–424. DOI: 10.11607/ijp.3776
Kern M, Sasse M. Ten-year survival of anterior all-ceramic resin-bonded fixed dental prostheses. J Adhes Dent 2011;13:407–410. DOI: 10.3290/j.jad.a22096
Sailer I, Hämmerle CHF. Zirconia ceramic single-retainer resin-bonded fixed dental prostheses (RBFDPs) after 4 years of clinical service: a retrospective clinical and volumetric study. Int J Periodontics Restor Dent 2014;34:333–343. DOI: 10.11607/prd.1842
Zhang L, Nie YG, Xie QF. Clinical application of anterior all-ceramic cantilevered resin-bonded fixed partial dentures. Zhonghua Kou Qiang Yi Xue Za Zhi 2008;43:209–211. DOI: 10.3321/j.issn:1002-0098.2008.04.006
Zhou TF, Wang XZ, Zhang GR. All-ceramic resin-bonded fixed partial denture made of IPS hot-pressed casting porcelain restore anterior missing teeth: a three-year clinical observation. Beijing Da Xue Xue Bao Yi Ban Xue 2011;43:77–80. DOI: 10.3969/j.issn.1671-167Χ. 2011.01.017
Hussey DL, Pagni C, Linden GJ. Performance of 400 adhesive bridges fitted in a restorative dentistry department. J Dent 1991;19:221–225. DOI: 10.1016/0300-5712(91)90122-f
Dalen AV, Feilzer AJ, Kleverlaan CJ. The influence of surface treatment and luting cement on in vitro behavior of two-unit cantilever resin-bonded bridges. Dent Mater 2005;21:625–632. DOI: 10.1016/j.dental.2004.11.004
Habibzadeh S, Khamisi F, Mosaddad SA, et al. Full-ceramic resin-bonded fixed dental prostheses: a systematic review. J Appl Biomater Funct Mater 2024;22:1–14. DOI: 10.1177/22808000241250118
Kern M, Thompson VP. Bonding to a glass-infiltrated alumina ceramic: adhesion methods and their durability. J Prosthet Dent 1995;73:240–249. DOI: 10.1016/s0022-3913(05)80200-8
Bilir H, Yuzbasioglu E, Sayar G, et al. CAD/CAM single-retainer monolithic zirconia ceramic resin-bonded fixed partial dentures bonded with two different resin cements: up to 40 months clinical results of a randomized-controlled pilot study. J Esthet Restor Dent 2022;34:1122–1131. DOI: 10.1111/jerd.12945
Shahdad SA, Cattell MJ, Ruiz JC, et al. Clinical evaluation of all-ceramic zirconia framework resin-bonded bridges. Eur J Prosthodont Restor Dent 2018;26:1–9. DOI: 10.1922/EJPRD_01810Shahdad09
Sasse M, Kern M. Survival of anterior cantilevered all-ceramic resin-bonded fixed dental prostheses made from zirconia ceramic. J Dent 2014;42:660–663. DOI: 10.1016/j.jdent.2014.02.021
Pjetursson BE, Sailer I, Latyshev A, et al. A systematic review and meta-analysis evaluating the survival, failure, and complication rates of veneered and monolithic all-ceramic implant-supported single crowns. Clin Oral Implants Res 2021;32:254–288. DOI: 10.1111/clr.13863
Mine A, Fujisawa M, Miura S, et al. Critical review about two myths in fixed dental prostheses: full-coverage vs. resin-bonded, non-cantilever vs. cantilever. Jpn Dent Sci Rev 2021;57:33–3. DOI: 10.1016/j.jdsr.2020.12.002