Citation Information :
Nemani SM, Chidambaranathan AS, Balasubramanium M. Outcome of Disinfection on Color Stability and Surface Roughness of Polyetheretherketone: An In Vitro Study. Int J Prosthodont Restor Dent 2024; 14 (2):80-85.
Purpose: To evaluate the color stability and surface roughness of PEEK after immersion in 10% povidone-iodine, 4% chlorhexidine gluconate, 2% glutaraldehyde, 5% sodium hypochlorite, and neutral soap disinfectant solutions.
Materials and methods: A total of 40 polyetheretherketone (PEEK) disk-shaped samples of diameter 10 and 3 mm thickness [according to International Organization for Standardization (ISO) 7491:2020] were sectioned and immersed in the disinfectant solution for 30 days for 10 minutes, twice a day. The disinfectant solutions included were 10% povidone-iodine, 4% chlorhexidine gluconate, 2% glutaraldehyde, 5% sodium hypochlorite, and neutral soap solution. Color stability was measured using a calorimeter after 30 days, and surface roughness was evaluated using a surface roughness tester. The color stability and surface roughness values were statistically analyzed using one-way analysis of variance (ANOVA) and Tukey's post hoc test.
Results: The mean color stability (ΔE) of PEEK after disinfection with neutral soap, 4% chlorhexidine gluconate, 5% sodium hypochlorite, 10% povidone-iodine, and 2% glutaraldehyde were 1.286 ± 0.208, 1.156 ± 0.261, 2.965 ± 0.292, 0.729 ± 0.309, and 0.601 ± 0.246, respectively, and the difference is statistically significant (p = 0.001). The post hoc test showed a significant difference in color change between different disinfectants except for chlorhexidine-neutral soap solution (p = 0.863) and glutaraldehyde-povidone-iodine (p = 0.871). The surface roughness of the control, chlorhexidine gluconate, sodium hypochlorite, neutral soap solution, povidone-iodine, and glutaraldehyde were 0.084 ± 0.026, 0.176 ± 0.080, 0.138 ± 0.064, 0.092 ±0.025, 0.086 ±0.033, and 0.095 ±0.032 µm, respectively, where p >0.05 for all group comparison except between chlorhexidine with neutral soap, glutaraldehyde, and sodium hypochlorite.
Conclusion: Polyetheretherketone materials immersed in 5% sodium hypochlorite showed increased color change, while the least change was observed with 2% glutaraldehyde. Around 4% chlorhexidine gluconate produced more surface roughness. Hence, 2% glutaraldehyde is recommended as a disinfectant for PEEK-based prostheses, and immersion of PEEK prosthesis in 5% sodium hypochlorite solution should be avoided.
Petersen PE, Bourgeois D, Bratthall D, et al. Oral health information systems – towards measuring progress in oral health promotion and disease prevention. Bull World Health Organ 2005;83(9):686–693. PMID: 16211160.
Mylonas P, Milward P, McAndrew R. Denture cleanliness and hygiene: an overview. Br Dent J 2022;233(1):20–26. DOI: 10.1038/s41415-022-4397-1
Craig RG, Obrien WJ, Powers JM Dental Materials, Properties and Manipulation, 7th edition. St. Louis: The CV Mosby co.; 1996. pp. 242–262.
Craig RG, Powers JM. Restorative Dental Material, 11th edition. St. Louis: Mosby Co.; 2002.
Health JR, Davenport JC, Jones PA. The abrasion of acrylic resin by cleaning pastes. J Oral Rehabil 1983;10(2):159. DOI: 10.1111/j.1365-2842.1983.tb00110.x
Jagger D, AL-Akhazam L, Harrison A, et al. The effectiveness of seven denture cleansers on tea stain removal from PMMA acrylic resin. Int J Prosthodont 2002;15(6):549–552. PMID: 12475160.
Kulak Y, Arikan A, Albak S, et al. Scanning electron microscopic examination of different cleansers surface contaminant removal from dentures. J Oral Rehabil 1997;24(3):209–215. PMID: 9131476.
Alqurashi H, Khurshid Z, Syed AUY, et al. Polyetheretherketone (PEKK): An emerging biomaterial for oral implants and dental prostheses. J Adv Res 2021;24(3):87–95. DOI: 10.1016/j.jare.2020.09.004
Najeeb S, Zafar MS, Khurshid Z, et al. Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics. J Prosthodont Res 2016;60:12–19. DOI: 10.1016/j.jpor.2015.10.001
Alexakou E, Damanaki M, Zoidis P, et al. PEEK high-performance polymers: a review of properties and clinical applications in prosthodontics and restorative dentistry. Eur J Prosthodont Restore Dent 2019;27(3):113–121. DOI: 10.1922/ejprd_01892zoidis09
Muhsin SA, Hatton PV, Johnson A, et al. Determination of polyetheretherketone (PEEK) mechanical properties as a denture material. Saudi Dent J 2019;31(3):382–391. DOI: 10.1016/j.sdentj.2019.03.005
Kuttuva Balasubramanian Sivaprakash Babu AD, Singaravel Chidambara Nathan A, Balasubramanium MK. Effect of laser surface treatment on shear bond strength between polyetheretherketone and heat-activated polymethylmethacrylate resin. J Prosthodont 2023;1–7. DOI: 10.1111/jopr.13744
Raj DA, Chander NG, Reddy JR, et al. Clinical acceptability of PEEK fixed dental prosthesis in partially edentulous patient - a one year single arm pilot study. J Oral Biol Craniofac Res 2020;10(4):523–528. DOI: 10.1016/j.jobcr.2020.08.006
Białobrzeska B, Jasiński R. Resistance to abrasive wear with regards to mechanical properties using low alloy cast steels examined with the use of a dry sand/rubber wheel tester. Materials (Basel) 2023;16(8):3052. DOI: 10.3390/ma16083052
Dutta A, Sharma M, Kumar S, et al. Effect of water sorption and solubility on two soft denture lining materials stored in three different mediums. Int J Prosthodont Restor Dent 2023;13(3):129–136. DOI: 10.5005/jp-journals-10019-1415
Arda T, Arikan A. An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps. J Prosthet Dent 2005;94(3):267–274. DOI: 10.1016/ j.prosdent.2005.06.009
Asad T, Watkinson AC, Huggett R. The effects of various disinfectant solutions on the surface hardness of an acrylic resin denture base material. Int J Prosthodont 1993;6(1):9–12. PMID: 8507335.
Bensel T, Jens JB, Lisa Z, et al. Effect of disinfectants on elastic modulus, flexural strength and colour stability of denture base resins. Open J Stomatol 2018;8:135–148. DOI: 10.4236/ojst.2018.84013
Zissis AJ, Polyzois GL, Yannikakis SA, et al. Surface roughness of denture materials: A comparative study. Int. J. Prosthodont 2000;13(2):136–140. PMID: 11203622.
Mayahara M, Kataoka R, Arimoto T, et al. Effects of surface roughness and dimorphism on the adhesion of Candida albicans to the surface of resins: Scanning electron microscope analyses of mode and number of adhesions. J Investig Clin Dent 2014;5(4):307–312. DOI: 10.1111/jicd.12055
Mei L, Busscher HJ, Van der Mei HC, et al. Influence of surface roughness on streptococcal adhesion forces to composite resins. Dent mater 2011;27(8):770–778. DOI: 10.1016/ j.dental. 2011.03.017
Bollen CML, Papaioanno W, Van Eldere J, et al. The influence of abutment surface roughness on plaque accumulation and peri-implant mucositis. Clin Oral Imp Res 1996;7(3):201–211. DOI: 10.1034/j.1600-0501.1996.070302.x
Davi LR, Felipucci DN, Souza RF, et al. Effect of denture cleansers on metal ion release and surface roughness of denture base materials. Bra J Dent J 2012;23(4):387–393. DOI: 10.1590/s0103-64402012000400013
Joshau N, Ahmed N, Rattan R. Evaluation and assessment of the colour stability of modified polymethyl methacrylate denture base materials and polyether ether ketone in a cast partial denture framework: an in-vitro study. Cureus 2023;15(11):e48189. DOI: 10.7759/ cureus.48189
Papathanasiou I, Papavasiliou G, Kamposiora P, et al. Effect of staining solutions on colour stability, gloss and surface roughness of removable partial dental prosthetic polymers. J Prosthodont 2022;31(1):65–71. DOI: 10.1111/jopr.13360
International Organization for Standardization. International Organization for Standardization. ISO 10477:2020 Dentistry-polymer-based crown and veneering materials Geneva: International Organization for Standardization; 2020. https://www.iso.org/obp/ui/#iso:std:iso:10477:ed-4:v1:en
Samanta P. Basic principles of colour measurement and colour matching of textiles and apparels. Colourimetry. IntechOpen; 2022
Wimmer T, Huffman AM, Eichberger M, et al. Two body wear rate of PEEK, CAD/CAM resin composite and PMMA: effect of specimen geometries, antagonist materials, and test set-up configuration. Dent Mater 2016;32(6):127–136. DOI: 10.1016/j.dental.2016.03.005
Heimer S, Schmidlin PR, Stawarczyk B. Discolouration of PMMA, composite, and PEEK. Clin Oral Investig 2017;21(4):1191–1200. DOI: 10.1007/s00784-016-1892-2
Piskin B, Sipahi C, Akin H. Effect of different chemical disinfectants on colour stability of acrylic denture teeth. J Prosthodont 2014;23(6):476–483. DOI: 10.1111/jopr.12131
Coelho SRG, da Silva MDD, Nunes TSBS, et al. Effect of immersion in disinfectants on the colour stability of denture base resins and artificial teeth obtained by 3D printing. J Prosthodont 2023;33(2):157–163. DOI: 10.1111/jopr.13663
Chowdhury D, Mazumdar P, Desai P, et al. Comparative evaluation of surface roughness and colour stability of nanohybrid composite resin after frequent exposure to tea, coffee, and coca-cola - an in vitro profilometric and image analysis study. J Conserv Dent 2020;23(4):395–401. DOI: 10.4103/jcd.jcd_401_20