Citation Information :
Elsherbini AN. Mini-poll Coping as an Alternative Attachment in Tooth-supported Overdenture Prosthesis: A Randomized Controlled Trial. Int J Prosthodont Restor Dent 2023; 13 (4):187-190.
Purpose: Evaluation of the resistance to dislodging resistance in the conventional overdenture, mini-poll coping, and telescopic crown.
Materials and methods: A sample size of 45 participants (15 in each group) was determined. Partially edentulous patients with only the two lower canines present were selected. After the fabrication of the three prostheses, using a force gauge, a dislodging pushing force was applied to the three groups at the labial frenal notches. Measurements were taken at insertion, after 1 and 3 months. One-way analysis of variance (ANOVA) and Tukey was calculated for the groups.
Results: The mean values for the conventional overdenture, mini-poll, and telescopic at insertion were 2.45 ± 0.095, 6.47 ± 0.101, and 6.66 ± 0.239 newton (N), respectively. The mean values for the conventional overdenture, mini-poll, and telescopic after 1 month were 3.58 ± 0.13, 8.5 ± 0.5, and 7.80 ± 0.435 N, respectively. The mean values for the conventional overdenture, mini-poll, and telescopic after 3 months were 3.7 ± 0.147, 8.56 ± 0.598, and 8.56 ± 0.452 N, respectively.
Conclusion: The mini-poll coping and telescopic crown recorded the highest retentive values, however, the mini-poll had the advantage of much lower cost when compared with the telescopic crown.
Elsherbini AN. Mini-poll coping as an alternative attachment In tooth supported over-denture prosthesis. Egypt Dent J 2019;65(4):3671–3675. DOI: 10.21608/EDJ.2019.76000
Samra RK, Bhide SV, Goyal C, et al. Tooth supported overdenture: a concept overshadowed but not yet forgotten. J Oral Res Rev 2015;7(1):16–21. DOI: 10.4103/2249-4987.160172
Bayer S, Stark H, Mues S, et al. Retention force measurement of telescopic crowns. Clin Oral Invest 2010;14(5):607–611. DOI: 10.1007/s00784-009-0315-z
Elsherbini AN, Niedermeier W. Comparison of different methods of abutment splinting and attachments on teeth kinetics (part I). World J Dent 2017;8:352–357. DOI: 10.5005/jp-journals-10015-1464
Fernandes FL, Chaware SH. Telescopic overdenture–an overlooked treatment modality for partially edentulous patients: a case report. J Contemp Dent 2018;8(3):148–152. DOI: 10.5005/jp-journals-10031-1240
Stillwell KD, Amir J. A clinical pathway for complete immediate denture therapy: successful prosthetic management for hopeless dentitions. Gen Dent 2008;6:380–389. PMID: 19284201.
Elsherbini AN, Nagy MM, Elsherbini NN. Stress analysis of over-denture abutments treated with two obturation techniques. Dent 3000 2021;9(1):77–84. DOI: 10.5195/d3000.2021.156
Mekawy NEL, Hegazy S, Raouf C. Impact of denture base materials on retention of tooth retained and supported mandibular overdenture. Periodon Prosthodon 2015; 1(1):1–8. DOI: 10.21767/2471-3082.100004
Zarb G, Hobkirk JA, Eckert SE, et al. Prosthodontic Treatment for Edentulous Patients, 13th edition. St. Louis: Elsevier Mosby; 2013. p. 157.
Basker RM, Davenport JC, Tomlin HR. Prosthetic Treatment of the Edentulous Patient, 4th edition. London: Macmillan; 2011. pp. 56–60.
Elsherbini AN, Alsharif TK, Elsherbini NN. Dislodging force resistance in hemi-mandibulectomy patients rehabilitated with acrylic resin and 3D-printed resin prostheses. World J Dent 2023;14(7):604–607. DOI: 10.5005/jp-journals-10015-2265
Rutkunas V, Mizutan H. Retentive and stabilizing properties of stud and magnetic attachments retaining mandibular overdenture, an in vitro study. Stomatologija BaltDent Maxillo J 2004;6:85–90.
Milić-Lemić A, Sredojević S, Radović K, et al. Retention force of overdenture retained with telescopic crowns: a comparison of polyether ether ketone and zirconia ceramic telescopic crowns. Srpski Arhiv Za Celokupno Lekarstvo 2020;148(0):25–25. DOI: 10.2298/SARH190923025M
Elsherbini AN, Niedermeier W. Repercussion of conventional complete mandibular denture versus single implant over-denture on retention and biting force. Open Access Macedonian J Med Sci 2021;9(D):186–189. DOI: 10.3889/oamjms.2021.6769
Hakkoum MA, Wazir G. Clinical study of patient satisfaction with telescopic overdentures. Int J Clin Dent 2019;12(4):253–258.